Viessmann · Mini-split troubleshooting

Install interconnecting power, wiring and piping at the indoor unit

DLFSHC

What is going on

Sequence for running the outdoor-to-indoor wiring and piping, then connecting them at the indoor unit.

Check in this order

  1. Run the interconnecting piping and wiring from the outdoor unit to the indoor unit.
  2. Pull an interconnecting cable through the wall hole from outside to inside.
  3. Lift the indoor unit into position and route the piping and drain through the wall hole.
  4. Hook the upper claw on the mounting plate and check the unit is secure.
  5. Open the front cover and remove the field wiring terminal block cover.
  6. Pull the interconnecting wire up from the back and position it at the terminal block.
  7. Push the lower part up on the wall and check the unit is hooked securely.
  8. Connect the outdoor wiring per the connection diagram (Fig. 21 or Fig. 22).
  9. Replace the field wiring cover and close the front cover.

Applies to: DLFSHC indoor units

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLFSHC installation instructions, p. 16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.