Indoor fan rules in HEATING mode

DLFSHC

What is going on

When the compressor is on, the fan can be set to high, medium, low, auto or mute. When coil temperature is low, the anti-cold air function runs the fan at low speed and the speed cannot be changed. When the room reaches setpoint, the compressor stops and the fan runs at minimum or set speed.

Check in this order

  1. Expect low fan speed during anti-cold air at startup.
  2. Expect the fan to stop when the coil temperature is below the set value.

Applies to: HEATING mode

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLFSHC service manual, p. 11. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.