Electronic expansion valve (EEV) control overview
What is going on
The valve is fully closed at power on. It opens for pressure equalizing when the compressor is off, and for starting control, frequency changes, defrost, high discharge temperature and discharge thermistor disconnection. Feedback control uses the target discharge pipe temperature.
Check in this order
- If the valve position looks wrong, check the power-on initialization and pressure equalizing behaviour.
- Check frequency changes and defrost, where the valve is controlled at a fixed opening.
Applies to: Outdoor unit expansion valve
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin FTXM-W/V service manual, p. 84. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.