PCB Board 8 removal: IPM module board and 24V board
What is going on
Removes the IPM module board and the 24V board. Wires to the DC fan motors, compressor and main control board are involved.
Check in this order
- Remove two screws to disconnect the power supply wires.
- Remove three screws to disconnect the compressor wires.
- Remove three screws and take off the radiator.
- Disconnect the wires between the IPM module board and the main control board.
- Remove the four screws, release the four hooks and remove the IPM module board.
- Remove one screw, disconnect the wires and remove the 24V board.
Applies to: PCB Board 8 in the outdoor unit
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: DLCURA service manual, p. 71 of 84. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.