Indoor unit wiring
What is going on
Wire the signal and power cables to the indoor terminal block, following the diagram on the control box cover.
Check in this order
- Turn off the main power before any wiring work.
- Strip the jacket of the signal cable to about 5.9 in (150 mm) and strip the conductor ends.
- Crimp u-lugs onto the wire ends with a crimper.
- Open the front panel and remove the electric control box cover.
- Thread the power and signal cables through the wire outlet.
- Match wire colours and labels to the terminal block and tighten each u-lug firmly.
- Clamp the cable so it is not loose and does not pull on the u-lugs.
- Reattach the electric box cover.
Applies to: Indoor unit power and interconnection wiring
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: D5FSOAH installation instructions, p. 22. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.