Carrier · Mini-split troubleshooting
Condensate drain and removal
What is going on
Drain must meet local plumbing codes. Indoor units have an internal trap, so no external trap is needed. Drain connections can be routed through alternate locations on most fan coils. If gravity drainage is not adequate, use the condensate pump accessory.
Check in this order
- Route the drain to meet local plumbing codes.
- Use an alternate drain location if the layout requires it.
- If gravity drain is not adequate, install the condensate pump accessory.
- Check drain sizes in the physical dimension tables.
Applies to: D5FSHA indoor units
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Carrier D5FSHA product data, p. 9. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.