Viessmann · Mini-split troubleshooting
Prepare the refrigerant piping exit
What is going on
Choose the piping exit side and open the unit to route the lines. Do not kink or dent the piping.
Check in this order
- Choose the side the piping will exit based on the wall hole position.
- If the hole is behind the unit, keep the knock-out panel in place.
- If the hole is to the side, remove the plastic knock-out panel on that side. Use needle nose pliers if needed.
- If piping is already embedded in the wall, skip to the drain hose connection.
- Bend the lines carefully away from the unit without denting them.
- Use the kickstand at the back of the unit to prop it against the mounting plate while connecting.
Applies to: DLFSHC indoor units
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: DLFSHC installation instructions, p. 11. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.