Carrier · Mini-split troubleshooting

Filter cleaning

D5FSFAH

What is going on

Remove and clean the air filters about once a month. Replace torn or excessively worn filters. Carbon filter can be washed with water every 6 months; manufacturer recommends replacing it every year.

Check in this order

  1. Turn off power at the outdoor disconnect switch (and the indoor unit switch if separate).
  2. Pull the left and right handles of the front panel, pull outward and open the panel.
  3. Press the claws on the right and left of the air filter down slightly, then pull upward to remove it.
  4. Hold the carbon filter frame tabs and remove the four claws to release the carbon filter.
  5. Clean the air filter with a vacuum or pure water; for heavy dust use a soft brush and mild detergent. Dry in a cool place, not in direct sunlight.
  6. Reinstall filters as they were and close the front panel. Do not run the unit without air filters.

Applies to: D5FSFAH floor console ductless system

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Carrier D5FSFAH owner's manual, p. 17. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.