All brands · Mini-split troubleshooting

Indoor unit leaking water

What is going on

Water is dripping from the indoor head of a mini split. Before you start, switch the unit off at the remote and, if you plan to open the cover, shut off the power at the disconnect as well. Nine times out of ten this is a drain problem or a dirty coil, and both are fixable without a gauge set.

Likely causes

  • Condensate drain line or pan clogged with slime and debris
  • Indoor head not level, or the drain line has no downward slope so water backs up
  • Dirty filters or coil restricting airflow, so the coil freezes and then drips as it thaws
  • Condensate pump failure on installs that use one

Check in this order

  1. Pull the filters and wash them, then look at the coil face for dirt buildup
  2. Place a level on the head and check the drain line slopes downward all the way out with no sags
  3. Clear the drain pan and drain line; a shop vac on the outside end or a flush of water usually shows where it is plugged
  4. If a condensate pump is installed, pour water into the reservoir and confirm it runs and discharges
  5. Look for ice on the coil and refrigerant lines, and if it is icing, find out why airflow is low before blaming the charge

Applies to: Ductless mini-splits

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.