All brands · Mini-split troubleshooting

Poor capacity / high head

What is going on

A mini split with poor capacity and high head pressure usually has a heat-rejection problem, so before assuming a refrigerant fault, confirm both coils and filters are clean. Turn off power at the disconnect before opening panels, and keep water away from electrical parts when washing coils.

Likely causes

  • Dirty indoor or outdoor coil
  • Dirty filters, one per indoor unit

Check in this order

  1. Disconnect power and cover the electrical parts
  2. Clean every filter
  3. Bib-wash the coils
  4. Check for clear airflow around the outdoor unit
  5. Restart and compare capacity and pressures against the manual
  6. Have a licensed tech check refrigerant if the problem remains

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.