Carrier · Mini-split troubleshooting

Unit starts and stops frequently

D5FUHAQ

What is going on

The compressor cycles on and off more often than normal.

Likely causes

  • Too much or too little refrigerant.
  • Incompressible gas or moisture in the system.
  • Blocked system circuit.
  • Broken compressor.
  • Voltage too high or too low.

Check in this order

  1. Check for leaks and recharge the system with refrigerant.
  2. Evacuate and recharge the system if gas or moisture has entered.
  3. Find the blocked circuit and replace the faulty part.
  4. Replace the compressor if it is broken.
  5. Install a manostat to regulate voltage if voltage is out of range.

Applies to: Refrigerant circuit and electrical supply

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Carrier D5FUHAQ Owner's Manual, p. 19. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.