Select piping exit direction and knock-out panel

D5FSHA

What is going on

Four exit directions are available: left-hand side, left rear, right rear, and right-hand side. The drain hose is recommended on the right-hand side when facing the back of the unit. Side exits should come out horizontally so the lower panel can be installed.

Check in this order

  1. Choose the exit side based on the wall hole position relative to the mounting plate.
  2. If the wall hole is behind the unit, keep the knock-out panel in place.
  3. If the wall hole is at the side, remove the plastic knock-out panel on that side, using needle-nose pliers if needed.
  4. Cut the knock-out panel only as needed for the actual pipe size.
  5. Route the pipes so the unit sits against the wall after installation.

Applies to: Indoor unit D5FSHA 6K to 36K

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Carrier D5FSHA installation manual, p. 16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.