Remove the evaporator subassembly

Vitocal IND-F

What is going on

The front panel, panel frame and both air outlet frame assemblies must be removed first.

Check in this order

  1. Remove the front panel, panel frame subassembly, upper air outlet frame and lower air outlet frame.
  2. Remove the 1 screw and take out the auxiliary water pan.
  3. Remove the one screw used for the ground connection.
  4. Pull out the coil temperature sensor.
  5. Remove the evaporator subassembly.

Applies to: DLFSFBH indoor floor console unit, 12K

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal IND-F DLFSFBH service manual, p. 46. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.