Make the refrigerant flare connections
What is going on
Clean square cuts and correct torque are needed for leak-free flare joints.
Check in this order
- Cut the pipe square at 90 degrees with a pipe cutter.
- Remove the service connection if the unit has one.
- Remove all burrs from the cut edge, and make sure none fall inside the tube.
- Remove the flare nuts from the indoor and outdoor unit connections.
- Install the correct size flare nut onto the tubing and make the flare. Check the flare nut spacing in Table 6.
- Apply a small amount of refrigerant oil to the flare.
- Align the pipe centre with the connection or service valve.
- Connect both the liquid and gas lines to the indoor unit.
- Tighten the flare nut with a torque wrench to the value in Table 7.
Applies to: DLFSHC indoor units
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: DLFSHC installation instructions, p. 16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.