Select the indoor unit installation location

DLFSHC

What is going on

Pick a wall location that allows good airflow, drainage and piping access, and avoid heat, moisture and electrical interference.

Check in this order

  1. Check the unit rating plate against the job specifications before installing.
  2. Confirm the wall is firm, level and strong enough to carry the unit without vibration.
  3. Leave room for maintenance, the line set and the drain line.
  4. Keep the unit at least 3.28 ft (1 m) from TVs, radios, computers and other electrical devices.
  5. Do not install near heat, steam, combustible gas, flammable items, doorways or direct sunlight.
  6. Do not install in bathrooms, laundry rooms, cabinets, factories, coastal salt-air areas, or areas with caustic gases or oil drilling.
  7. For units with an auxiliary electric heater, keep at least 3 ft (1 m) from combustible materials.
  8. Make sure there is room for the wall hole for the signal cable and refrigerant piping. Piping goes to the right side by default, but it can go to either side.

Applies to: DLFSHC indoor units

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLFSHC installation instructions, p. 9. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.