Fan and fan motor removal
What is going on
Removes the fan motor and fan assembly from the indoor unit. The evaporator subassembly must come out first.
Check in this order
- Remove the evaporator subassembly before removing the fan.
- Remove one screw and one hook, then take off the motor cover. There are two motor covers.
- Pull the fan motor and fan assembly out from the side.
- Remove the screw and take the fan motor out.
Applies to: DLFSFBH indoor unit, 12XAK
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal IND-F DLFSFBH service instructions, p. 48. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.