Carrier · Mini-split troubleshooting

Indoor unit mounting height and room limits

D5FSOAH

What is going on

Height and room size requirements for R-454B units.

Check in this order

  1. Mount the indoor unit at least 7.6 ft (2.3 m) above the floor.
  2. Room height must be at least 7.3 ft (2.2 m).
  3. Check the minimum room area in the refrigerant charge table for the actual charge and mounting height.

Applies to: R-454B indoor units

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Carrier D5FSOAH installation manual, p. 4. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.