Viessmann · Mini-split troubleshooting
Outdoor fan speed out of control
What is going on
The outdoor fan speed is either too low or too high. The unit stops and the LED shows the failure. The fault clears 30 seconds after the speed returns to normal.
Likely causes
- Outdoor fan speed below 100 RPM for 60 seconds
- Outdoor fan speed above 1500 RPM for 60 seconds
Check in this order
- Check the outdoor fan motor, its wiring and its control signal.
- Check that the fan blade turns freely and is not obstructed.
- Verify that the fan speed stays between 100 and 1500 RPM during operation.
Applies to: Outdoor fan, DLFSFBH 12K
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Viessmann Vitocal IND-F DLFSFBH service manual, p. 8. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.