Carrier · Mini-split troubleshooting
Built-in protections and special features
What is going on
The indoor unit provides automatic restart after power loss at the same operating conditions, indoor coil freeze protection, and indoor coil high-temperature protection in heat pump mode. The unit has diagnostics that warn of malfunctions and display error messages. A refrigerant leak detection sensor is fitted. The condensate pump has a liquid level sensor that stops cooling if the reservoir level is unacceptable.
Check in this order
- If the unit does not restart after a power failure, confirm it restarts at the same operating conditions as before the failure.
- If the indoor coil is freezing in cooling, check the freeze protection.
- If the condensate pump stops cooling, check the reservoir level and the liquid level sensor.
Applies to: D5FSHA indoor units
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Carrier D5FSHA product data, p. 12. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.