Carrier · Mini-split troubleshooting

Choosing the unit size and location

D5FSHA

What is going on

Select equipment that matches or slightly exceeds the peak load to improve humidity control and reduce cycling. For high sensible loads, size on sensible load and adjust for room wet bulb. Mount the indoor unit high on the wall in the middle of the selected wall, ideally on an outside wall. Keep the return and discharge clear of furniture and curtains.

Check in this order

  1. Size on peak load, or sensible load for high sensible-load rooms.
  2. Mount the indoor unit as high as possible, centered on the wall if possible.
  3. Keep the return and discharge unobstructed.
  4. Level the unit in all planes.
  5. Support the fan coil weight using the mounting bracket and the installation manual.

Applies to: D5FSHA indoor units

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Carrier D5FSHA product data, p. 9. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.