Electrical component checks on flammable refrigerant systems
What is going on
Make sure no electrical fault could cause ignition before power is restored.
Check in this order
- Disconnect all electrical supplies before removing sealed covers.
- Confirm capacitors are discharged in a safe way that avoids sparks.
- Confirm there are no exposed live parts or wiring while charging, recovering or purging.
- Confirm continuity of earth bonding.
- Check cables for wear, corrosion, pressure, vibration and sharp edges.
- Replace sealed electrical components and intrinsically safe parts only with manufacturer-specified parts.
- If a safety fault exists, do not connect power until it is fixed.
Applies to: Electrical devices in refrigerant system
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: D5FSCAH / D5FLCAH service manual, p. 7. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.