Viessmann · Mini-split troubleshooting

Temperature sensor identification

Vitocal IND-F

What is going on

The unit uses five temperature sensors: room (T1), indoor coil (T2), outdoor coil (T3), outdoor ambient (T4) and compressor discharge (T5). Test each sensor with a tester after disconnecting it from the PCB.

Check in this order

  1. Disconnect the temperature sensor from the PCB.
  2. Measure the resistance of the sensor with a tester.
  3. Identify the sensor T1 room, T2 indoor coil, T3 outdoor coil, T4 outdoor ambient, T5 compressor discharge.

Applies to: Indoor and outdoor temperature sensors

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLFSFBH Service Manual, p. 38. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.