Viessmann · Mini-split troubleshooting

Unit starts and stops frequently

Vitocal IND-O

What is going on

Check these points before calling a repair company.

Likely causes

  • Too much or too little refrigerant in the system.
  • Non-condensable gas or moisture in the system.
  • Refrigerant circuit blocked.
  • Compressor broken.
  • Voltage too high or too low.

Check in this order

  1. Check for leaks and recharge the system with refrigerant.
  2. Evacuate and recharge the system with refrigerant.
  3. Determine which circuit is blocked and replace the malfunctioning component.
  4. Replace the compressor.
  5. Install a voltage regulator to stabilize the supply voltage.

Applies to: Vitocal IND-O DLFSOAH, models 09XAK and 18XAK

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal IND-O DLFSOAH owner's manual, p. 17. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.