Daikin · Mini-split troubleshooting
Force cooling for testing
What is going on
Run the unit without waiting on thermostat.
Likely causes
- Only allowed when the outdoor unit has no error, is not in 3 minute standby and is off
Check in this order
- Hold the indoor ON/OFF switch 5 seconds (stops after about 15 minutes).
- Or from the remote Temp up, Temp down and Mode together, pick T, press Mode, pick cooling, press On/Off (stops after about 30 minutes).
Applies to: FTX30/36WVJU9 with RX30/36WMVJU9 or RK30/36WMVJU9
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Daikin FTX-W service manual SiUS042228E, Forced cooling operation, p.124. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.