Carrier · Mini-split troubleshooting

Refrigerant leak shutdown - single-zone

D5FSFA

What is going on

When a leak is detected the outdoor unit shuts off, the indoor fan runs at turbo speed, the louvers fully open and an audible alarm sounds. Codes EHC1 or EHC2 show on the indoor display.

Check in this order

  1. Call a qualified technician as soon as possible.
  2. Once the leak drops below the LFL threshold, the audible alarm resets after 2 minutes and the code clears after 5 minutes.
  3. To reset the audible alarm and code, power cycle the outdoor unit and keep it off for 5 minutes.

Applies to: Single-zone units with refrigerant leakage sensor

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Carrier D5FSFAH service manual, p. 16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.