Carrier · Mini-split troubleshooting
Fan motor removal (indoor floor console unit)
What is going on
Access and remove the fan motor and fan assembly from the indoor unit.
Check in this order
- Remove the one screw and one hook, then take off the motor cover. Two motor covers are fitted, so check both.
- Slide the fan motor and fan assembly out from the side.
- Remove the screw holding the fan motor and lift the fan motor out.
Applies to: D5FSFAH indoor floor console unit
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: D5FSFAH service manual, p. 56. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.