Viessmann · Mini-split troubleshooting

Wired remote control installation

Vitocal IND-F

What is going on

The connection point depends on the wired controller model and the indoor unit size.

Check in this order

  1. For KSACN0101AAA (timer), connect to the 4-pin connector on the display board, on all sizes 12 to 58.
  2. For KSACN0401AAA (7-day programmable) on size 12, cut the J1 jumper on the main control board, then connect to the 4-pin connector on the net module attached to CN20.
  3. For KSACN0501AAA (7-day programmable) on sizes 18 to 58, connect to the 4-pin connector on CN40 of the main control board.
  4. Follow the controller installation manual for setup.

Applies to: Wired controllers on sizes 12 to 58

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLFSFA and DLFLFA installation instructions, p. 13. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.