Outdoor unit panel removal (sizes 48-58, with 36 panel steps)

VITOCAL 100-S

What is going on

Procedure to open the DLCLRC outdoor unit casing: handle, top cover, water collecting cover, front right panel, front panel and right panel. Steps 1-4 on p. 42 are marked for sizes 48-58.

Check in this order

  1. Turn off the air conditioner and the power breaker before starting.
  2. Remove the 2 handle screws, then remove the handle.
  3. Remove the 4 top cover screws, then remove the top cover. Two of these screws sit under the handle.
  4. Remove the 2 water collecting cover screws, then remove the water collecting cover.
  5. Remove the 2 screws of the front right panel, then remove the front right panel.
  6. Remove the 7 front panel screws, then remove the front panel.
  7. Remove the 10 right panel screws, then remove the right panel.

Applies to: DLCLRC outdoor units, sizes 48 and 58 (36 steps on p. 39-41)

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLCLRC service manual, p. 42-44. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.