Hang the ceiling/floor indoor unit
What is going on
Mount the indoor unit on four suspension bolts. Two people are needed to lift it.
Check in this order
- Install the four suspension bolts.
- Lift the unit with two people and insert the bolts into the hanging holes. Secure with the supplied washers and nuts.
- Remove the side board and the grille before mounting.
- Set the unit on the hanging bolts using a block. Level it so it does not leak.
- Confirm drain tilt is at least 1/8 in per foot.
- Follow local codes for vibration isolation. Use a shockproof cushion if required.
- For ceiling installs, secure the conduit plate to the chassis. For wall installs, fix it to the electrical control box.
Applies to: Ceiling and wall mounted indoor units
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Carrier D5FCFA installation manual, p. 17-18. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.