Carrier · Mini-split troubleshooting
Charging a flammable refrigerant system
What is going on
Charge carefully and check for leaks before handover.
Check in this order
- Use only tools suited to flammable refrigerants.
- Keep charging hoses as short as possible.
- Keep cylinders upright.
- Earth the system before charging.
- Do not overfill the system.
- Pressure test with oxygen-free nitrogen before recharging.
- Leak test after charging and before commissioning, then again before leaving the site.
- Label the system after charging.
Applies to: Charging R454B systems
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: D5FSCAH / D5FLCAH service manual, p. 8. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.