Indoor unit mounting and location checks
What is going on
Mount the unit level in all planes and leave room for airflow. Keep the return and discharge free of furniture or curtains that could cause short cycling or recirculation.
Check in this order
- Level the unit in all planes.
- Provide clearance for airflow as in the installation figures.
- Position the unit in the most accessible spot above the ceiling.
- Keep return and discharge unobstructed.
- Duct to the middle of the wall where possible, toward an outside wall if available, facing the normal room occupants.
- Support the full fan coil weight at the mounting brackets.
Applies to: Ducted indoor units
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Viessmann DLFSDAH & DLFLDAH Technical Data Manual, p. 10. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.