Carrier · Mini-split troubleshooting
Indoor units mode conflict in multi-zone systems
What is going on
Indoor units cannot run cooling and heating at the same time. Heating has priority. A unit in cooling or fan mode will switch off or go to standby when another unit is set to heating. Mode conflict is shown in Table 9.
Likely causes
- One indoor unit set to heating while another is in cooling or fan mode
Check in this order
- If one unit is in cooling or fan mode and another is set to heating, the cooling or fan unit powers off.
- If one unit is heating and another is set to cooling or fan, the cooling or fan unit goes to standby.
- The heating unit keeps its mode in both cases.
Applies to: D5FSFAH multi-zone systems
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Carrier D5FSFAH service manual, p. 48. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.