System checks before handover
What is going on
Check the tubing, drain and insulation, then confirm the indoor unit functions.
Check in this order
- Final tubing check confirm factory tubing has not shifted, tubes do not rub each other or sheet metal, and feeder tube wire ties are tight.
- Conceal the tubing where possible and fasten the tubes to the outside wall when possible.
- Ensure the drain slopes downward along its full length.
- Insulate all tubing and connections.
- Seal the wall hole around cables and tubing.
- Confirm all remote buttons work, the display lights work, the air louver moves, and the drain flows.
Applies to: All sizes
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: DLFSFA and DLFLFA installation instructions, p. 13. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.