Connect the indoor drain hose

D5FCFA Ceiling/Floor Ductless

What is going on

Attach the drain hose to the indoor unit outlet and secure it so it cannot pull loose.

Likely causes

  • A bent or wrongly installed drain pipe can cause water to leak and trip the water-level switch.

Check in this order

  1. Insulate the drainpipe to prevent condensation and leaks.
  2. Push the hose mouth onto the unit outlet pipe, sheath it and clip it firmly with a pipe clasp.
  3. If an extended drain is used, add a protection tube to hold the indoor connection.
  4. Do not pull the drain pipe hard, as this can disconnect it.
  5. Check that the hose outlet discharges to a safe spot, since the outdoor unit discharges water in HEAT mode.

Applies to: Indoor drain piping

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Carrier D5FCFA installation manual, p. 18-19. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.