Viessmann · Mini-split troubleshooting

Zero crossing detection error

DLFSHC

What is going on

The control checks the zero crossing signal interval. The correct interval is 6 to 13 ms. If the interval is wrong for 240 seconds continuously, the unit stops and the LED shows the failure (EH 02).

Likely causes

  • Zero crossing signal interval outside 6 to 13 ms for 240 s

Check in this order

  1. Check the zero crossing signal timing on the indoor board.
  2. Check power supply quality at the indoor unit.

Applies to: Indoor unit power input

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLFSHC service manual, p. 10. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.