Mounting size 12K console (floor console only)

Vitocal IND-F

What is going on

Size 12K can only be mounted as a floor console, hung on wall hooks anchored into studs.

Check in this order

  1. Level the mounting hooks horizontally on the wall, keeping the minimum clearances.
  2. Anchor the hooks into wall studs with the mounting screws.
  3. Lift the unit and hang it on the hooks, checking the hooks sit in the matching holes on the back of the unit.
  4. Open the front panel by sliding the two stoppers toward the middle.
  5. Unhook the front panel string, remove the four screws, then lift the front cover's bottom 30 degrees and lift the top to remove it.

Applies to: Size 12K

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLFSFA and DLFLFA installation instructions, p. 8. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.