Carrier · Mini-split troubleshooting
Main control board and electronic control box removal
What is going on
Remove the panel first. Wear anti-static gloves. Steps 1 to 4 are for the main control board only; steps 5 and 6 are for the full electronic control box.
Check in this order
- Open the left cover of the panel.
- Remove 2 screws and take off the electronic control box cover.
- Remove 2 screws from the circuit breaker cover.
- Disconnect the connectors, then remove the main control board (released by 3 clips).
- To replace the full electronic control box, remove the 4 screws of the electronic control box subassembly.
- Remove the electronic control box subassembly.
Applies to: D5FSOAH
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Carrier D5FSOAH service manual, p. 54-56. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.