Carrier · Mini-split troubleshooting
Zero crossing detection error
What is going on
If the zero crossing interval is wrong for a continuous 240 s, the unit stops and the LED shows the failure. The correct interval is between 6 and 13 ms.
Check in this order
- Check the power supply to the indoor unit for a valid AC zero crossing signal.
- Restart the unit and check that the fault does not return.
Applies to: D5FSFAH 9K to 16K
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: D5FSFAH service manual, p. 14. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.