Daikin · Mini-split troubleshooting

Room does not cool or warm enough

FTXM WVJU9

What is going on

Air flow is present but the room does not reach the set temperature.

Likely causes

  • Airflow rate set too low.
  • Set temperature not suitable for the room.
  • Furniture or objects near the indoor unit.
  • ECONO or QUIET OUTDOOR UNIT mode limiting output.
  • Dirty air filters.
  • Blocked air inlet or outlet on indoor or outdoor unit.
  • Window or door open, or an exhaust fan running.
  • Room load, occupancy, or outdoor conditions beyond the unit's capacity.

Check in this order

  1. Raise the airflow rate setting.
  2. Check the set temperature.
  3. Clear furniture from around the indoor unit.
  4. Turn off ECONO or QUIET OUTDOOR UNIT if not wanted.
  5. Clean the air filters.
  6. Clear any blockage at the indoor and outdoor unit air paths.
  7. Close windows and doors and stop exhaust fans.
  8. In COOL with AUTO airflow, the airflow drops to a gentle breeze near set temperature. This is normal.

Applies to: Room air conditioner

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Daikin room air conditioner operation manual, p. 48. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.