What is going on

Check a temperature sensor by measuring its resistance with the sensor unplugged from the PCB. Compare the reading with the sensor resistance table in the Disassembly Instructions section.

Check in this order

  1. Turn off all power and disconnect the wires to avoid electric shock.
  2. Let the compressor and coil return to normal temperature before working on them.
  3. Disconnect the temperature sensor from the PCB.
  4. Measure the sensor resistance with a multi-meter.
  5. Compare the reading with the sensor resistance value table (see Disassembly Instructions, p. 39).

Applies to: DLFSFBH indoor and outdoor temperature sensors

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLFSFBH Service Manual, p. 35. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.