Carrier · Mini-split troubleshooting
Wiring the indoor unit to the outdoor unit and controller
What is going on
Use the wiring diagram label on the actual unit. The printed diagram on this page is largely unreadable.
Check in this order
- Refer to the diagram label on the unit, as the printed diagram is not fully legible.
- Match terminals 1, 2 and 3 on the indoor electronic control box to the outdoor unit terminals.
- Connect the wired controller to CN41 terminals HA and HB. The polarity is not important.
- Use only the specified wire and clamp the cables securely at the terminals.
- Make sure the control board cover closes properly after wiring.
Applies to: D5FSOAH indoor unit
More mini-split guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: D5FSOAH installation instructions, p. 14. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.