Carrier · Mini-split troubleshooting

Prepare refrigerant pipe ends (cut, deburr, flare)

D5FSOAH

What is going on

Clean, square and properly flared ends are needed for an airtight joint. Only the specified refrigerant may go into the system.

Check in this order

  1. Measure the distance between the indoor and outdoor units, then cut the pipe a little longer than that.
  2. Cut at a true 90° angle. Avoid oblique, rough or warped cuts, and do not dent or deform the pipe.
  3. Hold the pipe pointing down and remove all burrs with a reamer or deburring tool.
  4. Seal the pipe ends with PVC tape while preparing them to keep debris out.
  5. Sheath the pipe with insulation.
  6. Put the flare nuts on both ends facing the correct direction before flaring, because they cannot be turned after flaring.
  7. Remove the PVC tape just before flaring. Clamp the flare form so the pipe end extends beyond it.
  8. Place the flaring tool on the form and turn the handle clockwise until the flare is fully formed.
  9. Remove the tool and form, then check the flare for cracks and an even surface.

Applies to: Copper refrigerant line sets 6K-18K

More mini-split guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: D5FSOAH installation instructions, p. 19. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.