Viessmann heat pump error codes
226 codes (207 faults, 19 normal display and menu codes).
| Code | Meaning | Severity / type |
|---|---|---|
| 341 MCE | MCE error | High |
| 341 MCE error | MCE error | High |
| A2L | A2L sensor fault | High |
| E10 | Reserved | Menu / mode display |
| E11 | Reserved | Menu / mode display |
| E12 | Heating return temperature sensor failure | Medium |
| E13 | Heating outlet water temperature sensor failure | Medium |
| E14 | High pressure protection | High |
| E15 | Reserved | Menu / mode display |
| E16 | Low pressure protection | High |
| E17 | Reserved | Menu / mode display |
| E18 | Water flow protection | Medium |
| E19 | Electric heating overload protection | High |
| E20 | Exhaust temperature overprotection | High |
| E23 | Fan 1 overload speed limit | Medium |
| E24 | Fan 2 overload speed limit | Medium |
| E25 | Inlet/outlet water temperature difference exceeded | Medium |
| E26 | Outlet water over heat | High |
| E27 | Mixing outlet water temperature sensor failure | Medium |
| E28 | Hot water return temp sensor failure | Medium |
| E29 | Hot water outlet water temp sensor failure | Medium |
| E34 | High pressure protection, 3 times | Critical |
| E36 | Low pressure protection, 3 times | Critical |
| E38 | Water flow protection, 3 times | Critical |
| E39 | Electric heating protection, 3 times | Critical |
| E40 | Discharge over heat protection, 3 times | Critical |
| E42 | Inlet/outlet water temp difference exceeded, 3 times | Critical |
| E43 | Outlet water temp too low, 3 times | Critical |
| E44 | Outlet water over temperature protection, 3 times | Critical |
| E50 | Inlet water temp failure | Medium |
| E51 | Outlet water temp failure | Medium |
| E52 | Coil temp failure | Medium |
| E53 | Ambient temp failure | Medium |
| E54 | Suction temp failure | Medium |
| E55 | Anti-freeze temp failure | Medium |
| E56 | Coil outlet water temp sensor failure | Medium |
| E59 | EVI inlet temp failure | Medium |
| E68 | Hot water temp failure | Medium |
| E70 | IPM overheat | High |
| E71 | Compressor start failure | High |
| E72 | Compressor overcurrent (manual reset required) | High |
| E73 | Input voltage phase loss | High |
| E74 | IPM current sampling fault | High |
| E75 | Overheat protection of drive board devices | High |
| E76 | Pre-charge failure | Medium |
| E77 | DC bus over voltage | High |
| E78 | DC bus under voltage | High |
| E79 | AC input voltage under voltage | Medium |
| E80 | IPM overheat stop | High |
| E81 - E82 | Reserved | Menu / mode display |
| E83 | 15 VDC under voltage | Medium |
| E84 - E89 | Reserved | Menu / mode display |
| E90 | Compressor frequency not being maintained | Normal status |
| E91 | Compressor weak magnetic protection alarm | Medium |
| E92 | Power unit overheating alarm | Normal status |
| E93 | Reserved | Menu / mode display |
| E94 | AC input current down alarm | Medium |
| E95 | EEPROM failure warning | High |
| E96 - E99 | Reserved | Menu / mode display |
| E110 | Primary anti-freeze protection | Low |
| E111 | Secondary anti-freeze protection | Low |
| E112 | Anti-freeze protection | Medium |
| E114 | Room temp failure | Medium |
| E312 | Anti-freeze protection, 3 times | Critical |
| E510 | EVI outlet temp failure | Medium |
| E511 | Discharge temp failure | Medium |
| E513 | System 1 pressure sensor failure | Medium |
| E514 | Low ambient temp failure | Medium |
| E515 | Outlet temp too low protection | Medium |
| E611 | Fan 1 failure | High |
| E612 | Fan 2 failure | High |
| E613 | Communication failure (main board with fan motor module board) | High |
| E614 | Reserved | Menu / mode display |
| E615 | Communication failure (main board with fan motor 2 module board) | Medium |
| E710 | AC input over current shutdown | High |
| E711 | Input voltage sampling fault | Medium |
| E712 | DSP and PFC communication failure | High |
| E713 | Drive plate temperature fault | Medium |
| E714 | DSP and communication board communication failure | High |
| E715 | Main board communication failure | Medium |
| E810 - E815 | Reserved | Menu / mode display |
| E910 - E912 | Reserved | Menu / mode display |
| EC5C | High pressure sensor failure | Medium |
| EC07 | Outdoor fan speed outside normal range | Medium |
| EC50 | Outdoor temperature sensor error | Low |
| EC51 | Outdoor EEPROM parameter error or compressor driven chip EEPROM parameter error | High |
| EC52 | Open or short circuit of temperature sensor (outdoor) | Medium |
| EC53 | Outdoor temperature sensor open or short circuit (T3, T4, TP, T2B, TH) | Medium |
| EC54 | Open or short circuit of temperature sensor (outdoor) | Medium |
| EC55 | Open or short circuit of temperature sensor (outdoor) | Medium |
| EC56 | Open or short circuit of temperature sensor (outdoor) | Medium |
| EC57 | Refrigerant pipe temperature sensor error | Low |
| EC71 | Overcurrent failure of outdoor DC fan motor | High |
| EC72 | Lack phase failure of outdoor DC fan motor | High |
| EC73 | Zero-speed failure of outdoor DC fan motor | High |
| EH00 | EEPROM parameter error | High |
| EH00/EH0A | Indoor unit EEPROM parameter error | High |
| EH0E | Water-level alarm malfunction | Low |
| EH02 | Zero crossing detection error | Medium |
| EH03 | Indoor fan speed outside normal range | Medium |
| EH06 | Indoor PCB and display board communication error | Medium |
| EH60 | Indoor temperature sensor open or short circuit (T1, T2) | Medium |
| EH61 | Open or short circuit of temperature sensor (indoor) | Medium |
| EH62 | Open or short circuit of temperature sensor (indoor) | Medium |
| EH65 | Open or short circuit of temperature sensor (indoor) | Medium |
| EL0C | Refrigerant leakage detection | High |
| EL01 | Indoor and outdoor unit communication error | High |
| EL16 | Communication fault between outdoor main board and transit board | Medium |
| LC06 | High temperature protection of inverter module (IPM) | Critical |
| P5 | Indoor units mode conflict (multi-outdoor match) | Normal status |
| PC00 | IPM malfunction or IGBT over-strong current protection | Critical |
| PC0A | High temperature protection of condenser | Medium |
| PC0F | PFC module protection | Critical |
| PC0L | Low temperature protection of outdoor unit | Medium |
| PC01 | Overvoltage or low voltage protection | High |
| PC02 | Compressor top temperature or IPM high temperature / high pressure protection | Critical |
| PC03 | Low pressure protection | High |
| PC04 | Inverter compressor drive error | High |
| PC06 | Discharge temperature protection of compressor | High |
| PC08 | Current overload protection | High |
| PC10 | Outdoor unit low AC voltage protection | Medium |
| PC11 | Main control board DC bus high voltage protection | High |
| PC12 | Main control board DC bus high voltage protection / 341 MCE error | High |
| PC30 | System high pressure protection | Critical |
| PC31 | System low pressure protection | High |
| PC40 | Communication error between outdoor main chip and compressor driven chip | Medium |
| PC42 | Compressor start failure | High |
| PC43 | Outdoor compressor lack phase protection | High |
| PC44 | Outdoor unit zero speed protection | High |
| PC45 | Outdoor unit IR chip drive failure | High |
| PC46 | Compressor speed out of control | High |
| PC49 | Compressor overcurrent failure | Critical |
| PH90 | High temperature protection of evaporator | Medium |
| PH91 | Low temperature protection of evaporator | Medium |
| CON | Condensate level too high | Medium |
| Circuit Config. Error | Heating circuit configuration error | Low |
| Communication | Indoor to outdoor unit communication error | Medium |
| Cooling temp. | Cold buffer temperature sensor error | Medium |
| Curves Config. Error | Heating curve configuration error | Low |
| DF | Defrost display (normal) | Normal status |
| DHW Tank Temp. | DHW tank temperature sensor error | Medium |
| E(x) | Indoor unit error code E(x) | High |
| EC 07 | Outdoor fan speed outside normal range | Medium |
| EC 0d | Outdoor unit malfunction | High |
| EC 51 | Outdoor unit EEPROM parameter error | High |
| EC 52 | Condenser coil temperature sensor T3 open or shorted | Medium |
| EC 53 | Outdoor room temperature sensor T4 open or shorted | Medium |
| EC 54 | Compressor discharge temperature sensor TP open or shorted | Medium |
| EC 55 | IGBT temperature sensor TH open or shorted | Medium |
| EC 56 | Evaporator coil outlet temperature sensor T2B open or shorted | Medium |
| EC 72 | Missing phase failure of outdoor DC fan motor | High |
| EC(xx) | Indoor unit error code EC(xx) | High |
| EH 03 | Indoor fan speed outside normal range | Medium |
| EH 0E | Water-level alarm malfunction | Medium |
| EH 0b | Communication error between display board and main board | Medium |
| EH 31 | Upper indoor fan speed outside normal range | Medium |
| EH 32 | Lower indoor fan speed outside normal range | Medium |
| EH 3A | External fan DC bus voltage too low | Medium |
| EH 3b | External fan DC bus voltage too high | Medium |
| EH 60 | Indoor room temperature sensor T1 open or shorted | Medium |
| EH 61 | Evaporator coil temperature sensor T2 open or shorted | Medium |
| EH 62 | Open or short circuit of temperature sensor | Medium |
| EH 65 | Open or short circuit of temperature sensor | Medium |
| EH b3 | Communication error between wired controller and indoor unit | Low |
| EH bA | Communication fault between external fan module and indoor unit | Medium |
| EH(xx) | Indoor unit error code EH(xx) | High |
| EL 01 | Indoor / outdoor unit communication error | Medium |
| EL 0C | Refrigerant leakage detected | High |
| EL 16 | Communication malfunction between adapter board and outdoor main board | High |
| EL(xx) | Indoor unit error code EL(xx) | High |
| F(x) | Indoor unit error code F(x) | High |
| FC | FC display (normal) | Normal status |
| FH 07 | Communication fault between indoor unit and auto-lifting panel | Medium |
| FL 09 | Indoor and outdoor unit mismatch | High |
| FrE | Freeze protection active | High |
| GAS | A2L gas leak | Critical |
| HI | Compressor high speed | Normal status |
| HOP | High over pressure | High |
| HP Inlet Temp. | Outdoor unit inlet temperature sensor error | Medium |
| HP Low Pressure | Outdoor unit low refrigerant pressure | High |
| HP Outlet Temp. | Outdoor unit outlet temperature sensor error | Medium |
| Heat Pump Module | Heat pump error (outdoor unit) | High |
| IDU Pump | Indoor unit circulation pump error | Medium |
| Inlet Temp. | Return temperature sensor error | Medium |
| LC 06 | IPM module high temperature protection | High |
| LO | Compressor low speed | Normal status |
| LUP | Low under pressure | High |
| Low Battery | Low battery | Low |
| Low Pressure | Low heating medium pressure | High |
| NSU | Not set up | Medium |
| Outlet Temp. | Outlet temperature sensor error | Medium |
| Outside Temp. | Outside temperature sensor error | Medium |
| P(x) | Indoor unit error code P(x) | High |
| PC 00 | IPM malfunction or IGBT over-strong current protection | Critical |
| PC 01 | Over-voltage or low-voltage protection | High |
| PC 02 | Compressor top temperature or IPM high temperature protection | Critical |
| PC 03 | High or low pressure protection | High |
| PC 04 | Inverter compressor drive error | High |
| PC 06 | Discharge temperature protection of compressor | High |
| PC 08 | Current overload protection | High |
| PC 08/44/49 | Quick maintenance error code | Medium |
| PC 0A | High temperature protection of condenser | High |
| PC 0F | PFC module protection | High |
| PC 0L | Low ambient temperature protection | Low |
| PC 10 | Outdoor unit low AC voltage protection | High |
| PC 10/11/12 | Quick maintenance error code | Medium |
| PC 11 | Outdoor unit main board DC bus high voltage protection | High |
| PC 12 | Outdoor unit main board DC bus high voltage protection | High |
| PC 30 | High pressure protection | High |
| PC 31 | Low pressure protection | High |
| PC 40 | Communication error between outdoor main PCB and IPM board | High |
| PC 41 | Outdoor compressor current sampling circuit failure | Medium |
| PC 43 | Outdoor compressor lack phase protection | High |
| PC 44 | Outdoor unit zero speed protection | High |
| PC 45 | Outdoor unit IR chip drive failure | High |
| PC 46 | Compressor speed out of control | High |
| PC 49 | Compressor overcurrent failure | High |
| PC(xx) | Indoor unit error code PC(xx) | High |
| PH(xx) | Indoor unit error code PH(xx) | High |
| PL(xx) | Indoor unit error code PL(xx) | High |
| Power LED | Power indicator light | Normal status |
| Press. Sensor | System pressure sensor error (indoor unit) | Medium |
| Room Temp. | Room temperature sensor error | Medium |
| Temp. HC1 | Circuit 1 temperature sensor error | Medium |
| Temp. HC2 | Circuit 2 temperature sensor error | Medium |
| Thermal Cut-off | Fixed high limit tripped (indoor unit) | High |
Models covered
020028034004303404305107806AAK06XAK09AAK12AAJ12AAK12XAJ12XAK18AAK18K18K HH24AAK24K24K HH24XAK30AAK30K30K HH30XAK36K36K HH36XAK48K48K HH60K60K HHAM2V 020028AM2V 034043AM2V 051078AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056D5CSRADLCLRAH36AAKDLCLRAH48AAKDLCLRAH58AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCMRAH18BAKDLCMRAH27CAKDLCMRAH36DAKDLCMRAH48EAKDLCSRAH09AAKDLCSRAH12AAKDLCSRAH18AAKDLCSRAH24AAKDLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.