Viessmann · Heat pump
PC 30 High pressure protection
What the control is telling you
The outdoor pressure switch shuts the system down when high pressure rises above 4.4 MPa.
Applies to: DLCLRC outdoor unit
Likely causes
- Faulty or incorrectly wired high pressure switch or main control board connection
- Broken high pressure protector
- Outdoor ambient above 50°C
- Poor outdoor unit ventilation
- Dirty heat exchanger
- Outdoor fan not running properly or running outside normal speed range
- Refrigerant system not functioning properly
Test and repair steps
- Stop the unit before working on it.
- Check that the high pressure switch and main control board are wired correctly. Connect them if they are not.
- Disconnect the plug and measure the resistance of the high pressure protector. Replace the protector if it is broken.
- If the outdoor ambient is above 50°C, check that the outdoor unit ventilation is good.
- Check that the outdoor fan runs properly. If its speed is outside the normal range, follow the fan speed fault solution in the manual.
- If the heat exchanger is dirty, clean it.
- Check that the refrigerant system is functioning properly.
- If the problem remains, replace the outdoor main board.
Models that show this code
22 models in Vitocal 100-S
Other codes on the same units
- PC 0A High temperature protection of condenser
- PC 0F PFC module protection
- PC 31 Low pressure protection
- PC 40 Communication error between outdoor main PCB and IPM board
- PC 41 Outdoor compressor current sampling circuit failure
- PC 43 Outdoor compressor lack phase protection
- PC 44 Outdoor unit zero speed protection
- PC 45 Outdoor unit IR chip drive failure
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: DLCLRC Service Manual, p. 33. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.