Viessmann · Heat pump

E27 Mixing outlet water temperature sensor failure

Medium severity Vitocal 100-AW

What the control is telling you

The water mixer outlet temperature sensor circuit is open, shorted or the sensor is damaged.

Applies to: Vitocal 100-AW AM2V outdoor unit

Likely causes

  • Open circuit or short circuit of the water mixer outlet temperature sensor
  • Water mixer outlet temperature sensor damaged

Test and repair steps

  1. Check the connection and resistance of the water mixer outlet temperature sensor.
  2. Reconnect the sensor if the connection is faulty.
  3. Replace the water mixer outlet temperature sensor if it is damaged.

Models that show this code

7 models in Vitocal 100-AW

0200280340043034043051078AM2V 020028AM2V 034043AM2V 051078

Other codes on the same units

  • E23 Fan 1 overload speed limit
  • E24 Fan 2 overload speed limit
  • E25 Inlet/outlet water temperature difference exceeded
  • E26 Outlet water over heat
  • E28 Hot water return temp sensor failure
  • E29 Hot water outlet water temp sensor failure
  • E34 High pressure protection, 3 times
  • E36 Low pressure protection, 3 times

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Viessmann Vitocal 100-AW AM2V installation, service and operating instructions, p. 76. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.