E25 Inlet/outlet water temperature difference exceeded
What the control is telling you
The temperature difference between inlet and outlet water is too large.
Applies to: Vitocal 100-AW AM2V outdoor unit
Likely causes
- Insufficient water flow
Test and repair steps
- Check whether water flow is low; if so, work through the water flow protection steps (E18).
- Check whether the ambient temperature is above 86 °F (30 °C).
- Contact a professional technician if the fault remains.
Models that show this code
7 models in Vitocal 100-AW
Other codes on the same units
- E19 Electric heating overload protection
- E20 Exhaust temperature overprotection
- E23 Fan 1 overload speed limit
- E24 Fan 2 overload speed limit
- E26 Outlet water over heat
- E27 Mixing outlet water temperature sensor failure
- E28 Hot water return temp sensor failure
- E29 Hot water outlet water temp sensor failure
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Viessmann Vitocal 100-AW AM2V installation, service and operating instructions, p. 75. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.