Viessmann · Heat pump
EH02 Zero crossing detection error
What the control is telling you
The PCB does not receive a zero crossing signal for 4 minutes, or the zero crossing interval is abnormal. Applies only to units with an AC fan motor.
Applies to: DLFSHC indoor unit with AC fan motor only
Likely causes
- Loose or bad connection wires
- Indoor main PCB fault
- Power supply problem
Test and repair steps
- Check the connections and the power supply.
- Correct the connections and turn the unit on when the power supply is on.
- If the code remains, replace the indoor main PCB.
Other codes on the same units
- EC51 Outdoor EEPROM parameter error or compressor driven chip EEPROM parameter error
- EC53 Outdoor temperature sensor open or short circuit (T3, T4, TP, T2B, TH)
- EH03 Indoor fan speed outside normal range
- EH06 Indoor PCB and display board communication error
- EH60 Indoor temperature sensor open or short circuit (T1, T2)
- EL0C Refrigerant leakage detection
- EL01 Indoor and outdoor unit communication error
- PC00 IPM malfunction or IGBT over-strong current protection
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Viessmann Vitocal IND-H DLFSHC service manual, p. 19. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.