Viessmann · Heat pump

EH02 Zero crossing detection error

Medium severity DLFSHC

What the control is telling you

The PCB does not receive a zero crossing signal for 4 minutes, or the zero crossing interval is abnormal. Applies only to units with an AC fan motor.

Applies to: DLFSHC indoor unit with AC fan motor only

Likely causes

  • Loose or bad connection wires
  • Indoor main PCB fault
  • Power supply problem

Test and repair steps

  1. Check the connections and the power supply.
  2. Correct the connections and turn the unit on when the power supply is on.
  3. If the code remains, replace the indoor main PCB.

Other codes on the same units

  • EC51 Outdoor EEPROM parameter error or compressor driven chip EEPROM parameter error
  • EC53 Outdoor temperature sensor open or short circuit (T3, T4, TP, T2B, TH)
  • EH03 Indoor fan speed outside normal range
  • EH06 Indoor PCB and display board communication error
  • EH60 Indoor temperature sensor open or short circuit (T1, T2)
  • EL0C Refrigerant leakage detection
  • EL01 Indoor and outdoor unit communication error
  • PC00 IPM malfunction or IGBT over-strong current protection

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Viessmann Vitocal IND-H DLFSHC service manual, p. 19. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.