Viessmann · Heat pump
PC 0L Low ambient temperature protection
What the control is telling you
Operation lamp flashes 4 times, timer lamp flashing. In HEATING mode, if outdoor temperature stays below -13°F (-25°C) for 1 hour the unit shows PC 0L. It reverts to operation when outdoor temperature is above -7.6°F (-22°C) for 10 minutes and the compressor has stopped for one hour, or when outdoor temperature is above 23°F (-5°C) for 10 minutes.
Applies to: DLFSOAH09XAK, DLFSOAH18XAK
Likely causes
- Outdoor temperature below -13°F (-25°C) for 1 hour in HEATING mode
Other codes on the same units
- EL 01 Indoor / outdoor unit communication error
- EL 0C Refrigerant leakage detected
- FH 07 Communication fault between indoor unit and auto-lifting panel
- PC 00 IPM malfunction or IGBT over-strong current protection
- PC 01 Over-voltage or low-voltage protection
- PC 02 Compressor top temperature or IPM high temperature protection
- PC 03 High or low pressure protection
- PC 04 Inverter compressor drive error
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: DLFSOAH service manual, PDF p. 15. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.