LC 06 IPM module high temperature protection

High severity Vitocal 100-S

What the control is telling you

The IPM module temperature is above the set limit.

Applies to: DLCURA outdoor units

Likely causes

  • Blocked indoor or outdoor airflow
  • Loose PCB or IPM heat sink screws
  • Refrigerant system fault
  • Outdoor control PCB
  • Connection wires

Test and repair steps

  1. Check indoor and outdoor airflow; clear the air inlets, outlets or heat exchangers.
  2. Turn the power off and back on after 10 minutes.
  3. Check the PCB and IPM heat sink screws; tighten them and apply non-conductive heat transfer paste.
  4. Check the refrigerant system and repair it if faulty.
  5. Replace the outdoor control PCB if the problem remains.

Models that show this code

22 models in Vitocal 100-S

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Other codes on the same units

  • EH 65 Open or short circuit of temperature sensor
  • EL 16 Communication malfunction between adapter board and outdoor main board
  • FC FC display (normal)
  • FL 09 Indoor and outdoor unit mismatch
  • PC 06 Discharge temperature protection of compressor
  • PC 08 Current overload protection
  • PC 0A High temperature protection of condenser
  • PC 0F PFC module protection

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: DLCURA Service Manual, p. 34. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.