Viessmann · Heat pump

E68 Hot water temp failure

Medium severity Vitocal 100-AW

What the control is telling you

Hot water temperature sensor fault.

Applies to: Vitocal 100-AW AM2V outdoor unit

Likely causes

  • Open circuit or short circuit of the hot water sensor

Test and repair steps

  1. Check the suction pressure sensor connection.
  2. Replace the sensor with a new one if the connection is correct.

Models that show this code

7 models in Vitocal 100-AW

0200280340043034043051078AM2V 020028AM2V 034043AM2V 051078

Other codes on the same units

  • E50 Inlet water temp failure
  • E51 Outlet water temp failure
  • E52 Coil temp failure
  • E53 Ambient temp failure
  • E54 Suction temp failure
  • E55 Anti-freeze temp failure
  • E56 Coil outlet water temp sensor failure
  • E59 EVI inlet temp failure

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Viessmann Vitocal 100-AW AM2V installation, service and operating instructions, p. 78. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.